DANAK

Reg. No. 200 Accreditation for testing and calibration

Page: 1 2 3 4 5 6 7 all
EA Scope Equipment Quantity Range
Low
Limit
Range
High
Limit
U(CMC)
Low
Limit
U(CMC)
High
Limit
Working
Standard
Method Remark In Situ Location
Temperature Thermometers Temperature 0,01   °C 29,7646   °C 0,001  °C 0,001  °C Fixed points: Water TP, Gallium MP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 0,01   °C 156,5985   °C 0,001  °C 0,0025  °C Fixed points: Water TP, Indium MP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 0,01   °C 231,928   °C 0,001  °C 0,0025  °C Fixed Points: Water TP, Indium TP and Tin (TP) Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 0,01   °C 419,527   °C 0,001  °C 0,0025  °C Fixed Points: Water TP, Tin FP and Zinc FP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 0,01   °C 660,323   °C 0,001  °C 0,005  °C Fixed Points: Water TP, Tin FP, Zinc FP and Aluminium FP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature -189,3442   °C -189,3442   °C 0,00044  °C 0,00044  °C Fixed Point: Argon TP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature -38,8344   °C -38,8344   °C 0,0005  °C 0,0005  °C Fixed Point: Mercury TP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 0,01   °C 0,01   °C 0,00011  °C 0,00011  °C Fixed Point: Water TP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 29,7646   °C 29,7646   °C 0,0006  °C 0,0006  °C Fixed Point: Gallium MP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 156,5985   °C 156,5985   °C 0,0021  °C 0,0011  °C Fixed Point: Indium TP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 231,928   °C 231,928   °C 0,002  °C 0,002  °C Fixed Point: Tin FP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 419,527   °C 419,527   °C 0,002  °C 0,002  °C Fixed Point: Zinc FP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 660,323   °C 660,323   °C 0,0048  °C 0,0048  °C Fixed Point: Aluminium FP Internal procedure D1-1.2 Standard Platinum Resistance Thermometer (SPRT) TERM-Aarhus
Temperature Thermometers Temperature 0   °C 0   °C 0,0025  °C 0,0025  °C Ice Melting Point Internal procedure: D1-2.1, D1-2.2, D1-3.1, D1-4.1 Other Thermometers than SPRT's TERM-Aarhus
Temperature Thermometers Temperature -180   °C -80   °C 0,048  °C 0,024  °C Reference Thermometer Internal procedure D1-2.1, D1-2.2, D1-3.1, D1-4.1 Other thermometers than SPRT's by comparison in a cryostat TERM-Aarhus
Temperature Thermometers Temperature 40   °C 80   °C 0,007  °C 0,008  °C Reference Thermometer Internal procedure D1-2.1, D1-2.2, D1-3.1, D1-4.1 Other thermometers than SPRT's by comparison in liquid bath TERM-Aarhus
Temperature Thermometers Temperature -90   °C 30   °C 0,0045  °C 0,0036  °C Reference Thermometer Internal procedure: D1-2.1, D1-2.2, D1-3.1, D1-4.1 Other thermometers than SPRT's by comparison in liquid bath TERM-Aarhus
Temperature Thermometers Temperature 30   °C 40   °C 0,0063  °C 0,0063  °C Reference Thermometer Internal procedure D1-2.1, D1-2.2, D1-3.1, D1-4.1 Other thermometers than SPRT's by comparison in liquid bath TERM-Aarhus
Temperature Thermometers Temperature 40   °C 200   °C 0,0033  °C 0,0056  °C Reference Thermometer Internal procedure: D1-2.1, D1-2.2, D1-3.1, D1-4.1 Other thermometers than SPRT's by comparison in liquid bath TERM-Aarhus
Temperature Thermometers Temperature 200   °C 550   °C 0,0087  °C 0,0089  °C Reference Thermometer Internal procedure: D1-2.1, D1-2.2, D1-3.1, D1-4.1 Other thermometers than SPRT's by comparison in liquid bath TERM-Aarhus
Temperature Thermometers Temperature 200   °C 340   °C 0,45  °C 0,45  °C Reference Thermometer Internal procedure: D1-2.1, D1-2.2, D1-3.1, D1-4.1 Other thermometers than SPRT's by comparison in a horisontal tube furnace TERM-Aarhus
Temperature Thermometers Temperature 340   °C 1100   °C 0,45  °C 0,86  °C Reference Thermometer Internal procedure: D1-2.1, D1-2.2, D1-3.1, D1-4.1 Other thermometers than SPRT's by comparison in a horisontal tube furnace TERM-Aarhus
Temperature Thermostat baths and ovens Temperature -100   °C -45   °C 0,026  °C 0,009  °C Reference Thermometer Internal procedure: D1-5.1 Dry Block Calibrators TERM-Aarhus
Temperature Thermostat baths and ovens Temperature -45   °C 155   °C 0,009  °C 0,009  °C Reference Thermometer Internal procedure: D1-5.1 Dry Block Calibrators and Micro-Baths TERM-Aarhus
Temperature Thermostat baths and ovens Temperature 155   °C 350   °C 0,047  °C 0,047  °C Reference Thermometer Intern procedure: D1-5.1 Dry Block Calibrators and Micro-Baths TERM-Aarhus
Temperature Thermostat baths and ovens Temperature 350   °C 660   °C 0,13  °C 0,13  °C Reference Thermometer Intern procedure: D1-5.1 Dry Block Calibrators and Micro-Baths TERM-Aarhus
Temperature Thermostat baths and ovens Temperature 660   °C 1200   °C 0,7  °C 1,2  °C Reference Thermometer Internal procedure: D1-5.1 Dry Block Calibrators TERM-Aarhus
Electricity DC and LF Electrical equipment (DC) Voltage (DC) 0   V 0,2   V 0,35  μV 0,75  μV Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Voltage (DC) 0,2   V 2   V 1,8  μV 6,1  μV Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Voltage (DC) 2   V 20   V 10  μV 68  μV Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Voltage (DC) 20   V 200   V 0,24  mV 0,89  mV Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (AC) Voltage (AC)
(40 Hz - 10 kHz )
200   V 1000   V 58  ppm 230  ppm Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Voltage (DC) 200   V 1000   V 2,8  mV 5,6  mV Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (AC) Voltage (AC)
(10 Hz - 10 kHz )
0,1   V 0,2   V 61  ppm 200  ppm Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (AC) Voltage (AC)
(10 kHz - 100 kHz )
0,1   V 0,2   V 180  ppm 410  ppm Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (AC) Voltage (AC)
(10 Hz - 10 kHz )
0,2   V 2   V 39  ppm 180  ppm Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (AC) Voltage (AC)
(10 kHz - 100 kHz )
0,2   V 2   V 120  ppm 0,65  % Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (AC) Voltage (AC)
(10 Hz - 10 kHz )
2   V 20   V 40  ppm 200  ppm Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (AC) Voltage (AC)
(10 kHz - 100 kHz )
2   V 20   V 170  ppm 0,66  % Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (AC) Voltage (AC)
(10 Hz - 10 kHz )
20   V 200   V 43  ppm 240  ppm Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (AC) Voltage (AC)
(10 kHz - 100 kHz )
20   V 200   V 120  ppm 0,65  % Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Resistance 0   Ω 2   Ω 6,8  μΩ 26  μΩ Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Resistance 2   Ω 20   Ω 42  μΩ 0,16  mΩ Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Resistance 20   Ω 200   Ω 0,32  mΩ 1,5  mΩ Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Resistance 200   Ω 2   kΩ 3,2  mΩ 15  mΩ Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Resistance 2   kΩ 20   kΩ 32  mΩ 0,15  Ω Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Resistance 20   kΩ 200   kΩ 0,32  Ω 1,5  Ω Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Resistance 200   kΩ 2   MΩ 4  Ω 16  Ω Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Resistance 2   MΩ 20   MΩ 18  Ω 0,34  kΩ Digital Multimeter Internal procedure D1-7.1, D1-7.2, D1-7.3 El-Aarhus
Electricity DC and LF Electrical equipment (DC) Resistance 20   MΩ 200   MΩ 16  kΩ 23  kΩ Digital Multimeter Internal procedure: D1-7.1, D1-7.2, D1-7.3 El-Aarhus